12.1 Inch Maternal Fetal Monitor For Pregnant Built In Rechargeable Lithium Battery

Brand Name : Rainbow

Model Number : PM-9000E

Certification : ISO13485

Place of Origin : Hunan, China

MOQ : 1 unit

Price : $409.00 - $550.00

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 30000units/year

Delivery Time : Within 3 days

Packaging Details : Anti-collision film+ Carton box dimension:40*30*35cm Gross weight: 6.3Kg

Brand name : Rainbow

Model number : PM-9000E

Instrument classification : Class Ⅱ

Power supply : AC,DC

Warranty : 1 year

Product name : maternal fetal monitor

Display : 12.1'' TFT display

Feature : Testing device

Contact Now

China Low Price 12.1 Inch Maternal-Fetal Monitor For Pregnant Use Built-In Rechargeable Lithium Battery

12.1 Inch Maternal Fetal Monitor For Pregnant Built In Rechargeable Lithium Battery

Features

Module with a new high-precision, high-precision measurement parameters, reliable quality and stable performance. High brightness 12.1 inches and high resolution color TFT LCD, the waveform data is clearly visible.

•Jog shuttle operation, in English logo button, easy to use, simple and intuitive operation.

•Three-channel synchronous acquisition ECG, all leads seven-channel synchronous ECG display.

•Multiple display interface: standards, large font, all leads, trend charts coexist meet more clinical needs.

•All aluminum internal structure design has good shock resistance to meet the mobile environment.

• Oxygen using the new digital technology, when making weak perfusion and finger jitter measurements, it is more accurate.

•Detection and analysis of ST segment automatic detection, arrhythmia analysis, analysis of drug concentrations drop table.

•The new design of full isolation floating, anti defibrillation anti electrosurgical interference, to meet the surgery. Ward and other harsh environments.

•NIBP double overvoltage drift control and many other technology to ensure accurate measurement, to protect patient safety.

• Powerful storage capability, the entire fully parametric trend chart data, ECG

•Waveform storage playback, power-down save function.

•Automatic sound and light dual alarm ,the alarm can be set upper and lower limits.

•Fan-less design,clean, low power consumption and improve the lifespan of the instrument.

•Lightweight and sturdy body, easy to carry, suitable for adults, children and newborns.

•Support for wired and wireless networking capabilities, and support online software upgrades.

Removing the optional built-in rechargeable lithium battery, AC-DC dual-use, lightweight, energy-saving and environmental protection.

•Can be equipped with built-in two-channel thermal array recorder, real-time waveforms and print icon.

•Widely used in hospital departments bedside care ward, ICU/CCU, operating room, emergency center, family custody.

•Optional wall bracket, mobile frame, visits backpack.

Technical Parameters

Fetal heart rate

Probe:nine wafer, wide beam, pulsed operation mode and high sensitivity

Ultrasound intensity: less than 1mW/cm2

Operating frequency:1.0MHz

Signal Processing: dedicated digital signal processing unit

Maximun Audio Output Power:1.5W

Contractions pressure:10-100 pressure unit

Ultrasonic probe output

In accordance with the provisions of the international convention in 1992,IEC1157, negative peak sound pressure of not more than 1 trillion Pa(MPa).Beam sound intensity does not exceed 20mW/cm2(mW/cm2). Sound intensity spatial peak temporal average density of less than 100mW/cm(mW/cm2).The models sound intensity does not exceed 1mw/cm2

Coupling agent(GEL)

Viscous water-based sets of objects. On the skin without stimulation, no allergies. Chemically stable, inhibit bacterial type.

ECG

Lead Select:All leads,I, II, III,aVF, aVR, aVL.V1-6 chest leads display

Gain Select:×1, ×2, ×4, ×0.5 fourth gear

Frequency: 0.5Hz-100Hz

Comman mode signal rejection: greater than 70dB

Scanning speed: 12.5mm/s, 25mm/s,50mm/s standard three files

Heart Rate Accuracy:±5 beats/min

Calibration signal: 1mV(peak value, accuracy ±3%)

ST segment detection: Measuring range

Use Standard:ANSI/AAMI EC 13-2002 standard

Response time:1s

Alarm:sound and light alarm

Heart rate alarm range(preset value exceeds the preset alarm): Upper limit adjustable between 1-250 times/min

The lower limit adjustable between 0-249 times/min

SPO2 oxygen saturation

Range:0-100%

Official pay Accuracy:1%

Resolution:1%

Pulse rate:20-250 beats/min

Response time:1s

Alarm:sound and light alarm

Heart rate alarm range(preset value exceeds the preset alarm):Upper Limit:adjustable between 1%-100%

Lower Limit:adjustable between 0%-99%

RESP respiration

Respiratory frequency range:0-60 times/min

Accuracy:±1bpm

Response time:1s

Gain selection:×1, ×2, ×4, ×0.5 fourth gear

Alarm:sound and light alarm

Alarm preset range (above the preset alarm value) Upper limit:adjustable between a 10-100beats/min

Lower limit:adjustable between 0-99 times/min

NIBP blood pressure

Technology: Oscillometric

Measuring method: positive and negative two-way measurement data is more accurate

Operating modes:manual/automatic

Units of measurement:mmHg/Kpa

Overvoltage protection:double protection

Measurement time:less than 45s

Cuff pressure range:0-250mmHg

Blood pressure measurement accuracy:ANS/AAMI sp10-2002 standard error of the mean and standard deviation values

Initial inflatable cuff: 180mmHg(newborn children 120mmHg 70mmHg)

Follow inflatable cuff:original+30mmHg systolic blood pressure measurement range:systolic:60-250mmHg

DBP:40-220mmHq

Average pressure:45-235mmHq

Response time:1s

Alarm:sound and light alarm:(Alarm preset range exceeds the preset alarm value) Systolic blood pressure limit is adjustable between 1-255mmHg

Adjustable between a lower 0-254mmHq

Diastolic blood pressure limit is adjustable between 1-255mmHg

Adjustable between a lower 0-254mmHq

Use standard:ANSI/AAMA SP10-2002 standard

TEMP

Technical:highly sensitive thermistor probe

Temperature measurement range:20℃-45℃

Resolution:0.1%

Temperature accuracy:±1℃

Response time:1s

Alarm:sound and light alarm

Alarm preset range(above the preset alarm value)

Limit:adjustable between 20.1℃-45.5℃

Limit:adjustable between 20℃-45.4℃

Standard configuration:

PM-9000E maternal fetal monitor×1 set,

build-in dual channel thermal printer×1 set,

triple fetal probe×1 set,

ultrasound gel×1 bottom,

probe bandages×1 set,

standard 5-leads ECG conductance joint connecting cables×1 set,

standard adult blood pressure cuffs×1 set,

adult SPO2 probe×1 set,

TEMP probe×1 set,

power plug line×1 set,

grounding wire×1 set,

English operation manual×1 set.

Three certificates×1 set.

12.1 Inch Maternal Fetal Monitor For Pregnant Built In Rechargeable Lithium Battery


Product Tags:

12.1Inch Maternal Fetal Monitor

      

Rechargeable Maternal Fetal Monitor

      

PM-9000E Fetal Monitoring Machine

      
Quality 12.1 Inch Maternal Fetal Monitor For Pregnant Built In Rechargeable Lithium Battery for sale

12.1 Inch Maternal Fetal Monitor For Pregnant Built In Rechargeable Lithium Battery Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hunan Province Rainbow Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)